Programmable Type Transducers
-

MICAR 2
Programmable digital transducers
PRODUCT ADVANTAGES
- Class 0.2 / insulation 4 kV
- Up to 4 configurable analogue outputs
- 32 measurable electrical quantities
- DIN-rail or panel mounting
- Option of 2 or 4 on-off outputs
- Communicationand programming via optical head if local or via Ethernet network or RS485 output if remote
- Electrical network supervision and display of the energy values, harmonics and THD with the E.view+ software
GENERAL SPECIFICATIONS
- Quantities measured: 1, 2, 3 or 4 selected among 32 electrical quantities
- Configuration: at the factory or by the user with the E.view+ software
- Current inputs: 1 A and 5 A
- Voltage inputs: 100 to 400 V (ph-ph) or 57.7 to 230 V (ph-N)
- Transfer curves/strong>: linear, 2 slopes, quadratic
- Output signal: configurable between – 20 mA and + 20 mA
- Response time: 350 ms
- Operating frequency: 50 Hz or 60 Hz
- Auxiliary power source with wide dynamic range: 80 to 264 Vac/dc or 19 to 57 Vdc
- Compliance with CE directive
-
TRIAD 2
- Accuracy up to 0.1% on all measurements
- Response time programmable down to to 50 ms on each measurement and each analogue channel
- 200 ms for a class of 0.2%
- Up to 4 analogue channels
- Ethernet communication available with ModBus and JBus protocols
- Overvoltage category or “so-called installation category” III (at 300 Vrms). This means better creepage distances and greater distances in the air between traces, so the cost of the product is greater due to the need to increase the insulating barriers
- Product with double insulation
- Test voltage or “so-called insulation voltage” = 4 kV / 50 Hz – 1 min
- Product configurable at the factory or by the customer with the TRIADJUST 2 software available for download from the ENERDIS website.
- TRIADJUST 2 easy-to-use software for configuration, display and recording.
- >Product designed and manufactured IN FRANCE.
Model T3xy
- Dimension: 120x80x120.5 mm
- Measurements on single phase, Three phase balanced or unbalanced networks 3 / 4 wires
- 0, 1, 2, 3 or 4 analogue output(s)
- Measurements of V, U, I, F, P, Q, S, FP, Tan φ , Cos φ , φ Fund, φ U, φ V
- Adjustable accuracy class from 0.1% to 1% (depending on response time)
- Adjustable response time from 50ms to 1s
- Ethernet or RS485 communication option
- Configuration via TRIADJUST 2 software
Model T1xy
- Dimension: 60x80x120.5 mm
- Measurements on single phase or Three phase balanced networks 3 / 4 wires
- 0 or 1 analogue output
- Measurements of V, U, I, F, P, Q, S, FP, Tan φ , Cos φ , φFund
- Adjustable accuracy class from 0.1% to 1% (depending on response time)
- Adjustable response time from 50ms to 1s
- Ethernet or RS485 communication option
- Configuration via TRIADJUST 2 software
- Alarm Annunciator
- Busbar Systems
- Bushing
- Battery
- Connection For Aircraft On The Ground
- Connector and Clamps
- Capacitors
- Contactors
- Cable Tray
- Dynamic Line Rating
- Disconnectors
- Fault Circuit Indicator
- SmartLink
- Radio Faulted Circuit Indicator System
- Radio Receiver Series 1570 – Control/Transmitter
- Smartlink Series 5000 Cellular RTU for Faulted Circuit Indicator
- Radio Receivers handheld or RTU/SCADA
- Overcurrent Trip Automatic Time Reset Indicator Series
- Voltage-Reset Fault Circuit Indicator
- Current-Reset Fault Circuit Indicator (up to 35kV)
- Adaptive Trip Faulted Circuit Indicator (up to 35kV)
- Overhead Faulted Circiut Indicator (up to 69kV)
- Fault Circuit Indicator
- Fan
- Industrial Cabinets & Enclosures
- Industrial Plugs And Sockets
- Internet Of Things
- Interlocks
- Insulator
- Lighting
- Low Voltage Busduct
- Medium Voltage Insulated Busduct
- Metering
- Photoelectric Controls
- FPN 7840 – Series Shorting Caps, Open Caps
- FP-N1038 Series Shorting Caps, Open Caps
- FP-N7700 Series Instant Response
- Flush-Mount Controls
- Swivel Directional Control
- FP-FT Series/SFT Conduit Mount
- 24 Hour Electromechanical Time Switches
- 7 Day and 24-Hour Electronic Time Switches
- Wi-OLC Photocontrol (Node)
- Wi-OLC Base Station
- Partial Discharge
- Plastic Enclosure & Boxes
- Power Converters
- Power Quality
- Protection Relays
- Reactors
- Arc Suppression Coils
- HVDC-Reactors
- Thyristor Controlled Shunt Reactors
- Static VAR Compensators
- Shunt Reactors
- The Capacitor/Filter Protection Relay CPR 97
- Filter reactors with de Q’ing rings
- Filter Reactors
- Load Flow Control Reactors
- Duplex Reactors
- Buffer reactor for Electric Arc Furnaces (EAF)
- Design Features of Air-Core Dry Type Reactors
- Reactors
- Renewable Energy
- Resistors
- Secondary Equipment
- Starter
- Safety
- Surge
- Temperature Controls & Sensors
- Safe LHD Cable
- Power Controllers
- 1-phase solide state relay – RP6
- RE controller Series
- Statop 24 Series
- Statop 48 Series
- Statop 96 Series
- Thyritop Series
- Synchro coupler
- PYROTRACER VIDEO C.A 650
- PYROTRACER PC
- Minitracer
- ECOTRACER
- ECOPOINTER C.A 625
- Surface sensors
- Ambient temperature sensors
- Temperature Assemblies for Industries
- Multipoint temperature assemblies for chemical reactors
- ATEX or PED pyrometer assemblies
- Accessories for controllers
- Test & Measurement
- Power and Energy Analyser
- Single Phase Ratiometer
- Micro-Ohmmeters
- Earth & Resistivity Testers and Adapter for Pylon Earth Measurement
- Digital Insulation Testers
- Installation Tester
- Current probe sfor oscilloscopes
- Non-Contact Thermometers
- Training Cases
- Earth and Resistivity Testers
- High Voltage
- Thermographic Camera
- Power and Harmonic Wattmeter Clamps
- Energy Analyzers for Three-Phase Electrical Networks
- Electrical Equipment Testers
- Earth Clamps and Loop Testers
- Digital Multimeter
- Power Quality Analyser
- Traction System
- Transducers & Signal Transmitters
- Transformer
- Low Voltage Transformer
- Medium Voltage
- Voltage Transformer for Outdoor Application
- Current Transformer for Outdoor Application – Standard Type
- Current Transformer for Outdoor Application – Compact Type
- Voltage Transformer for Outdoor Application – Head Type
- Current Transformer for Outdoor Application – Head Type
- Voltage Transformer for Indoor Application – Small Type
- Voltage Transformer for Indoor Application – Narrow Type
- Voltage Transformer for Indoor Application – Large Type
- Current Transformer for Indoor Application – Head Type
- Current Transformer for Indoor Application – Block Type
- Current Transformer for Indoor Application – Ring Type
- Current Transformer for Indoor Application – Bushing Type
- High Voltage
- Transformer Accessories
- Power Transformer