Digital Display Meters

  • CCT

    CCT

    Remote reading of metering pulses and ON-OFF signals

    The CCT collects and stores in real time the pulses from various energy meters (electricity, water, gas) or ON-OFF signals (circuit-breaker status, alarm trigger, door opening) and transmits them via its RS485 digital output to an energy management system such as WinThor. It accepts all types of metering units (m3, m3/hour, litres, kWh, etc.).

    •   8 inputs individually programmed as metering pulse inputs or ON-OFF inputs.
    •   Pulse inputs:   – Energy management: memorization of load curves by recording the last 4,032 average values for each of the 8 channels (Example: 28 days’ recording for an integration period of 10 minutes),     – Memorization of the last 12 monthly metering indices and the general metering index
    •   ON-OFF inputs:   – Metering and date-stamping of events: date-stamping of the status change of an ON-OFF input accompanied by memorization of the statuses of all the ON-OFF inputs.     – Memorization of the last 50 status changes.

    Brochure & Catalog

    CCT Brochure & Catalog

  • ULYS Meters

    Ulys

    PRODUCT ADVANTAGES

    • TOTALLY COMPLIANT IEC 62053-21 standard Class 1
    • PARTIAL ENERGY METERING for periodical energy management
    • PROGRAMMABLE PRODUCTS: transformation ratios, pulse transmitters

    Types of product;
    1) ULYS EMd (Direct single phase

    • Double-tariff active energy metering for single-phase LV networks
    • 1 pulse output
    • P and Maximum P measurement
    • 90 A Direct current inputs
    • Partial (Zero-Resettable) metering

    2) ULYS ETd (Direct three phase)

    • Single-tariff active energy metering for three-phase LV/MV networks
    • 1 pulse output
    • P and Maximum P measurement
    • 90 A Direct current inputs
    • Partial (Zero-Resettable) metering

    3) ULYS ET (Three phase)

    • Single-tariff active energy metering for three-phase LV/MV networks
    • 1 pulse output
    • P and Maximum P measurement
    • Current inputs on CT 1 A or 5 A
    • Partial (Zero-Resettable) metering

    4) ULYS ETi (Three phase insulated

    • Single-tariff active energy metering for three-phase LV/MV networks
    • 1 pulse output
    • P and Maximum P measurement
    • Insulated current inputs on CT 1 A or 5 A
    • Partial (Zero-Resettable) metering

    5) ULYS ETDT (Three phase Double Tariff)

    • Double-tariff active energy metering for three-phase LV/MV networks
    • 1 pulse output
    • P and Maximum P measurement
    • Insulated current inputs on CT 1 A or 5 A
    • Partial (Zero-Resettable) metering

    6) ULYS ETAR (Three phase Active/Reactive

    • Active/reactive energy metering for three-phase LV/MV networks
    • 2 pulse outputs
    • P,Q and Maximum P,Q measurements
    • Insulated current inputs on CT 1 A or 5 A
    • Partial (Zero-Resettable) metering

    Brochure & Catalog

    ULYS brochure