Digital Display Meters
-
CCT
Remote reading of metering pulses and ON-OFF signals
The CCT collects and stores in real time the pulses from various energy meters (electricity, water, gas) or ON-OFF signals (circuit-breaker status, alarm trigger, door opening) and transmits them via its RS485 digital output to an energy management system such as WinThor. It accepts all types of metering units (m3, m3/hour, litres, kWh, etc.).
- 8 inputs individually programmed as metering pulse inputs or ON-OFF inputs.
- Pulse inputs: – Energy management: memorization of load curves by recording the last 4,032 average values for each of the 8 channels (Example: 28 days’ recording for an integration period of 10 minutes), – Memorization of the last 12 monthly metering indices and the general metering index
- ON-OFF inputs: – Metering and date-stamping of events: date-stamping of the status change of an ON-OFF input accompanied by memorization of the statuses of all the ON-OFF inputs. – Memorization of the last 50 status changes.
Brochure & Catalog
-
Ulys
PRODUCT ADVANTAGES
- TOTALLY COMPLIANT IEC 62053-21 standard Class 1
- PARTIAL ENERGY METERING for periodical energy management
- PROGRAMMABLE PRODUCTS: transformation ratios, pulse transmitters
Types of product;
1) ULYS EMd (Direct single phase- Double-tariff active energy metering for single-phase LV networks
- 1 pulse output
- P and Maximum P measurement
- 90 A Direct current inputs
- Partial (Zero-Resettable) metering
2) ULYS ETd (Direct three phase)
- Single-tariff active energy metering for three-phase LV/MV networks
- 1 pulse output
- P and Maximum P measurement
- 90 A Direct current inputs
- Partial (Zero-Resettable) metering
3) ULYS ET (Three phase)
- Single-tariff active energy metering for three-phase LV/MV networks
- 1 pulse output
- P and Maximum P measurement
- Current inputs on CT 1 A or 5 A
- Partial (Zero-Resettable) metering
4) ULYS ETi (Three phase insulated
- Single-tariff active energy metering for three-phase LV/MV networks
- 1 pulse output
- P and Maximum P measurement
- Insulated current inputs on CT 1 A or 5 A
- Partial (Zero-Resettable) metering
5) ULYS ETDT (Three phase Double Tariff)
- Double-tariff active energy metering for three-phase LV/MV networks
- 1 pulse output
- P and Maximum P measurement
- Insulated current inputs on CT 1 A or 5 A
- Partial (Zero-Resettable) metering
6) ULYS ETAR (Three phase Active/Reactive
- Active/reactive energy metering for three-phase LV/MV networks
- 2 pulse outputs
- P,Q and Maximum P,Q measurements
- Insulated current inputs on CT 1 A or 5 A
- Partial (Zero-Resettable) metering
Brochure & Catalog
- Alarm Annunciator
- Busbar Systems
- Bushing
- Battery
- Connection For Aircraft On The Ground
- Connector and Clamps
- Capacitors
- Contactors
- Cable Tray
- Dynamic Line Rating
- Disconnectors
- Fault Circuit Indicator
- SmartLink
- Radio Faulted Circuit Indicator System
- Radio Receiver Series 1570 – Control/Transmitter
- Smartlink Series 5000 Cellular RTU for Faulted Circuit Indicator
- Radio Receivers handheld or RTU/SCADA
- Overcurrent Trip Automatic Time Reset Indicator Series
- Voltage-Reset Fault Circuit Indicator
- Current-Reset Fault Circuit Indicator (up to 35kV)
- Adaptive Trip Faulted Circuit Indicator (up to 35kV)
- Overhead Faulted Circiut Indicator (up to 69kV)
- Fault Circuit Indicator
- Fan
- Industrial Cabinets & Enclosures
- Industrial Plugs And Sockets
- Internet Of Things
- Interlocks
- Insulator
- Lighting
- Low Voltage Busduct
- Medium Voltage Insulated Busduct
- Metering
- Photoelectric Controls
- FPN 7840 – Series Shorting Caps, Open Caps
- FP-N1038 Series Shorting Caps, Open Caps
- FP-N7700 Series Instant Response
- Flush-Mount Controls
- Swivel Directional Control
- FP-FT Series/SFT Conduit Mount
- 24 Hour Electromechanical Time Switches
- 7 Day and 24-Hour Electronic Time Switches
- Wi-OLC Photocontrol (Node)
- Wi-OLC Base Station
- Partial Discharge
- Plastic Enclosure & Boxes
- Power Converters
- Power Quality
- Protection Relays
- Reactors
- Arc Suppression Coils
- HVDC-Reactors
- Thyristor Controlled Shunt Reactors
- Static VAR Compensators
- Shunt Reactors
- The Capacitor/Filter Protection Relay CPR 97
- Filter reactors with de Q’ing rings
- Filter Reactors
- Load Flow Control Reactors
- Duplex Reactors
- Buffer reactor for Electric Arc Furnaces (EAF)
- Design Features of Air-Core Dry Type Reactors
- Reactors
- Renewable Energy
- Resistors
- Secondary Equipment
- Starter
- Safety
- Surge
- Temperature Controls & Sensors
- Safe LHD Cable
- Power Controllers
- 1-phase solide state relay – RP6
- RE controller Series
- Statop 24 Series
- Statop 48 Series
- Statop 96 Series
- Thyritop Series
- Synchro coupler
- PYROTRACER VIDEO C.A 650
- PYROTRACER PC
- Minitracer
- ECOTRACER
- ECOPOINTER C.A 625
- Surface sensors
- Ambient temperature sensors
- Temperature Assemblies for Industries
- Multipoint temperature assemblies for chemical reactors
- ATEX or PED pyrometer assemblies
- Accessories for controllers
- Test & Measurement
- Power and Energy Analyser
- Single Phase Ratiometer
- Micro-Ohmmeters
- Earth & Resistivity Testers and Adapter for Pylon Earth Measurement
- Digital Insulation Testers
- Installation Tester
- Current probe sfor oscilloscopes
- Non-Contact Thermometers
- Training Cases
- Earth and Resistivity Testers
- High Voltage
- Thermographic Camera
- Power and Harmonic Wattmeter Clamps
- Energy Analyzers for Three-Phase Electrical Networks
- Electrical Equipment Testers
- Earth Clamps and Loop Testers
- Digital Multimeter
- Power Quality Analyser
- Traction System
- Transducers & Signal Transmitters
- Transformer
- Low Voltage Transformer
- Medium Voltage
- Voltage Transformer for Outdoor Application
- Current Transformer for Outdoor Application – Standard Type
- Current Transformer for Outdoor Application – Compact Type
- Voltage Transformer for Outdoor Application – Head Type
- Current Transformer for Outdoor Application – Head Type
- Voltage Transformer for Indoor Application – Small Type
- Voltage Transformer for Indoor Application – Narrow Type
- Voltage Transformer for Indoor Application – Large Type
- Current Transformer for Indoor Application – Head Type
- Current Transformer for Indoor Application – Block Type
- Current Transformer for Indoor Application – Ring Type
- Current Transformer for Indoor Application – Bushing Type
- High Voltage
- Transformer Accessories
- Power Transformer