Statop 48 Series

  • Statop 4897 4899

    Statop 4897 / 4899

    COMM 4851 digital data exchange software

    Multi-sensor input 48x96mm digital controllers.

    Ramp, temperature guarantee and timer functions.
    STATOP 4897: 1 regulation and 2 alarm channels
    STATOP 4899: 2 “hot/cold” regulation channels and 2 alarms.

    • Easy and safe to use by PID self-adjustment and fuzzy logic
    • Multi-sensor input: configurable for thermocouples (J, K, T, E, B, R, S or N) or for Pt100 probes (2 or 3-wire)
    • Twin 10,000-count display: measurement in red and set point in green. Five (or six) LEDS: 1 (or 2) regulation LED(s), 2 alarm LEDs and 2 °C or °F unit LEDs
    • Control outputs: relay, logic or analogue current
    • Configurable alarm outputs on relays
    • RS 485 digital transmission available as an option
    • Power supply 90 to 260VAC. On request: 20 to 32VAC/DC

    Family codes STATOP 4897 and STATOP 4899

    • Family: ST4897 4513
    • Family: ST4897 4513
    • Output: 10 relay – 20 logic voltage – 30 analogue (4…20mA)
    • Alarm: 00 without -20 with 2 alarms

  • Statop4850

    Statop 4850

    COMM 4851 digital data exchange software

    Leakproof IP 65 front panel – Universal input 48x48mm digital controllers.
    1 regulation channel and 2 alarms or 2 “hot/cold” regulation channels and 1 alarm.
    Ramp, temperature guarantee and timer functions.

    • Easy and safe to use with PID self-adjustment and fuzzy logic
    • Universal input: configurable for thermocouples (J, K, T, E, B, R, S or N) or for Pt100 probes (2 or 3-wire), analogue voltage or current
    • 10000-count twin display: measurement in red and set point in green. Five LEDS: 1 regulation LED, 2 alarm LEDs and 2 °C or °F unit LEDS
    • Regulation outputs: relay or logic (voltage) or analogue (current or voltage)
    • Configurable alarm output available on relays
    • RS 485 digital transmission available as an option
    • Power supply 90 to 260VAC. On request: 20 to 32VAC/DC

    Family code STATOP 4850

    • Family: ST4850 4513
    • Output 1: 1 relay – 2 logic voltage. – 3 analogue (4…20mA)
    • Output 2: 0 without – 1 relay
    • Alarm: 0 without – 1 relay
    • RS485 transmission: 0 without – 1 with

  • statop4849

    Statop 4849

    Multi-sensor input 48x48mm digital controllers.
    1 regulation channel and 1 alarm, available as an option.
    Ramp functions, guarantee of temperature and timer.

    • Easy and safe to use by PID self-adjustment and fuzzy logic
    • Multi-sensor input: configurable for thermocouples (J, K, T, E, B, R, S or N) or for Pt100 probes (2 or 3-wire)
      On request: linear voltage input (-10 to + 60 mV)
    • Twin, 10000-count display: measurement in red and set point in green. Two LEDs: 1 red alarm and 1 green regulation LED
    • Regulation output: relay or logic or analogue voltage
    • Configurable alarm output on relay
    • Power supply 90 to 260VAC. On request: 20 to 32VAC/DC

    Family code STATOP 4849

    • Family: ST4849
    • Power supply: (90/260) 90 to 260VAC
    • Output: (REL) relay – (LOG) logic – (4/20)
      analogue 4…20mA
    • Alarm: (AL) with alarm

  • Statop 4896-60

    Statop 4896-60

    Specially designed for thermal processes

    48x96mm Digital controllers (1/8 DIN)
    1 control channel and 2 alarms or two “hot-cold” control channels and one alarm. Temperature ramp and timer functions. Easy and safe to use with auto-adjusting PID and fuzzy logic.

    • IP50 front-panel protection
    • Configurable universal input: for thermocouples (J, K, T, E, B, R, S, N or L) or Pt100 Ω probes or analogue voltage or analogue current
    • Programmable process input: analogue piloting of control setting
    • Logic input: to commute a control setting
    • 2 x 10,000-count display, measurement in red and setting in green
    • Control output: relay or logic voltage or analogue 4…20mA, 0…10V
    • Configurable alarm output
    • RS 485 digital transmission optional
    • 90 to 260VAC power supply

  • Statop4896-30

    Statop 4896-30

    48x96mm digital controllers (1/8 DIN)
    1 control channel and 1 alarm or 2 “hot-cold” control channels without alarm. Temperature ramp and timer functions. Easy and safe to use with auto-adjusting PID and fuzzy logic.

    • IP50 front panel protection
    • Configurable temperature input: thermocouples (J, K, T, E, B, R, S, N or L) or Pt100 Ω probes
    • 2 x 10,000-count display, measurement in red and setting in green
    • Control output: relay or logic voltage or analogue 4…20mA, 0…10V
    • Configurable alarm output optional
    • RS 485 digital transmission optional
    • 90 to 260VAC power supply

  • Statop48-60

    Statop 48-60

    Specially designed for thermal processes

    48x48mm Digital controllers (1/16 DIN)
    1 control channel and 2 alarms or two “hot-cold” control channels and one alarm. Temperature ramp and timer functions. Easy and safe to use with auto-adjusting PID and fuzzy logic.

    • IP65 front panel protection
    • Configurable universal input: for thermocouples (J, K, T, E, B, R, S, N or L) or Pt100 Ω probes or analogue voltage or analogue current
    • Programmable process input: analogue piloting of control setting
    • Logic input: to commute a control setting
    • 2 x 10,000-count display, measurement in red and setting in green
    • Control output: relay or logic voltage or analogue 4…20mA, 0…10V
    • Configurable alarm output
    • RS 485 digital transmission optional
    • 90 to 260VAC power supply

  • statop4830

    Statop 4830

    48x48mm Digital controllers (1/16 DIN)
    1 control channel and 1 alarm or 2 hot-cold control channels without alarm. Temperature ramp and timer functions. Easy and safe to use with auto-adjusting PID and fuzzy logic.

    • IP50 front panel protection
    • Configurable temperature input: thermocouples (J, K, T, E, B, R, S, N or L) or Pt100 Ω probes
    • 2 x 10,000-count display, measurement in red and setting in green
    • Control output: relay or logic voltage or analogue 4…20mA, 0…10V
    • Configurable alarm output optional
    • RS 485 digital transmission optional
    • 90 to 260VAC power supply

  • Statop4815

    Statop 4815

    48x48mm digital controllers (1/16 DIN)
    1 control channel and 1 alarm. Temperature ramp and timer functions. Easy and safe to use with auto-adjusting PID and fuzzy logic.

    • IP30 front panel protection
    • Configurable temperature input: thermocouples (J, K, T, E, B, R, S, N or L) or Pt100 Ω probes
    • 10,000-count display
    • Control output: relay or logic voltage or analogue 4…20mA, 0…10V
    • Configurable alarm output optional
    • RS 485 digital transmission optional
    • 90 to 260VAC power supply

  • Statop 4897 4899

    Statop 4897 / 4899

    COMM 4851 digital data exchange software

    Multi-sensor input 48x96mm digital controllers.

    Ramp, temperature guarantee and timer functions.
    STATOP 4897: 1 regulation and 2 alarm channels
    STATOP 4899: 2 “hot/cold” regulation channels and 2 alarms.

    • Easy and safe to use by PID self-adjustment and fuzzy logic
    • Multi-sensor input: configurable for thermocouples (J, K, T, E, B, R, S or N) or for Pt100 probes (2 or 3-wire)
    • Twin 10,000-count display: measurement in red and set point in green. Five (or six) LEDS: 1 (or 2) regulation LED(s), 2 alarm LEDs and 2 °C or °F unit LEDs
    • Control outputs: relay, logic or analogue current
    • Configurable alarm outputs on relays
    • RS 485 digital transmission available as an option
    • Power supply 90 to 260VAC. On request: 20 to 32VAC/DC

    Family codes STATOP 4897 and STATOP 4899

    • Family: ST4897 4513
    • Family: ST4897 4513
    • Output: 10 relay – 20 logic voltage – 30 analogue (4…20mA)
    • Alarm: 00 without -20 with 2 alarms